24-hour and intermittent supply runs
Turn a snapshot into a 24 hour extended period run with a daily demand pattern, and model intermittent supply of a few hours a day.
A snapshot run (Total Duration 0) solves one instant. It is enough to check pressures at a chosen demand level, but tanks do not fill or drain, pumps do not switch, and demand does not change through the day. An extended period run solves the network hour by hour so you can see all of that.
An extended period run needs three things: a duration, a demand pattern, and time steps. Project > Set up a 24-Hour Run... asks for all three in plain words and writes them into the project in one go.
Step 1: Simulation type
| Choice | Duration | Use it for |
|---|---|---|
| Single snapshot | 0:00 | One instant, for checking pressures at a chosen demand level. |
| 24 hours | 24:00 | One day: the daily cycle of demand and tank levels. |
| 48 hours | 48:00 | Two days: shows whether tanks end the day where they started. |
| 7 days | 168:00 | A week: for water age and slow tank drift. |
The window shows the project's current Total Duration at the top.
Step 2: Demand pattern
A pattern is a list of multipliers, one per hour, that makes each junction's base demand rise and fall. Choose one of three options:
- Keep the project's patterns: leave patterns as they are.
- Continuous supply, from the library: pick a ready-made 24 hour shape.
- Intermittent supply windows: say when water is on, and PipePilot builds the pattern.
The library holds these patterns:
| Pattern | ID | Shape |
|---|---|---|
| Urban 24x7 (morning and evening peaks) | URBAN24X7 | Continuous supply in a town: a sharp 6 to 9 am peak, a smaller 6 to 8 pm peak and low night use. Peak multiplier 2.5. |
| Rural JJM continuous | RURALJJM | Continuous supply to household taps in a village (Jal Jeevan Mission): use bunched around early morning and evening chores. Peak multiplier 3.0. |
| Flat | FLAT | The same demand every hour. Useful to check a network before adding a daily shape. |
| Intermittent, 2 h morning + 2 h evening | INT2X2 | Water on 6 to 8 am and 6 to 8 pm only. The whole day's volume is drawn in those 4 hours, so the multiplier inside them is 6.0. |
A chart previews the 24 multipliers, with the peak multiplier, the mean, and the hours of the day the water is on. Then give the pattern a Pattern ID and choose how it is used:
- Make it the Default Pattern: every junction without a pattern of its own follows it.
- Assign it to the N junctions with no pattern, where N is how many there are: writes the pattern onto each such junction directly.
Junctions that already have a pattern keep it either way. If the ID you type already exists, the window warns that the existing pattern will be replaced.
Intermittent supply
Many Indian towns supply water for a few hours a day. During those hours consumers fill sumps and overhead tanks, so the whole day's volume is drawn in a short time. PipePilot keeps the daily volume and squeezes it into the supply hours:
- Press + Add window for each supply window, and give a Start hour (0 to 23) and a length in whole hours. Windows may wrap past midnight.
- The multiplier inside the windows is 24 divided by the number of supply hours. Four hours of supply gives 24 / 4 = 6.0; outside the windows it is 0.
- Daily volume factor scales the day when supply falls short of demand. 1 delivers the full daily demand; 0.8 delivers 80% of it.
The library pattern Intermittent, 2 h morning + 2 h evening is this rule applied to 6 to 8 am and 6 to 8 pm.
Step 3: Time steps
| Step | Default | Meaning |
|---|---|---|
| Hydraulic time step | 1:00 | How often EPANET re-solves flows and pressures. It also takes shorter steps by itself when a tank fills or empties or a control acts. |
| Pattern time step | 1:00 | How long each multiplier lasts. Fixed at 1:00 when you choose a library or intermittent pattern, because those have one value per hour. |
| Reporting time step | 1:00 | How often results are kept for the time slider, graphs and tables. |
| Quality time step | 0:05 | The step for water age and chlorine. It cannot be longer than the hydraulic step. |
Times are entered as hours:minutes. Pattern Start and Report Start are left as they are; change them on the Times page of Project > Analysis Options....
Apply and run
Press Apply to write the setup into the project, or Apply and Run to write it and run straight away. Any problem (an empty pattern ID, a quality step longer than the hydraulic step) is shown at the bottom of the window before anything changes.
Then step through the day with the Time slider on the Browser's Map tab, or play it with the animation buttons. A Time Series graph of an ESR's level and of the pressure at a tail-end junction tells you most of what you need. See Running and reading results.
Base demand is the average, the pattern supplies the peak
EPANET multiplies each junction's base demand by its pattern. For an extended period run the base demand should be the average demand and the pattern should supply the peak. Do not also multiply the base demand by a peak factor, or the peak is counted twice. Demand allocation explains how to get the average demand from a population.